LWL-EHR TTL

LWL-EHR TTL
  • Transmission length up to 1500 m
  • Reconversion of optical signals into electrical signals and generation of status signals
  • Transmission error detection via checksum (CRC)
  • High-precision transmission of signals (Jitter <100 ns)
  • Constant delay time <20 μs
  • Automatic channel switchover in realtime upon failure of one fiber-optic channel
Objednací číslo: 11090946
Výrobce: Baumer Electric AG
Dostupnost: na dotaz

 

Chcete znát dostupnost zboží? Vložte produkt do poptávky a my se vám ozveme.
Potřebujete poradit s výběrem nebo najít alternativu? Kontaktujte produktového specialistu.

Poradím vám

Ondřej Štěpánek
Ondřej Štěpánek
Produktový manažer
BAUMER
Ondřej Štěpánek - QR Kontakt
Parametry
Nákresy
Ke stažení
Podpora
Podobné produkty

Parametry

Elektrické vlastnosti

Napájecí napětí: 9...30 VDC
Spotřeba: ≤300 mA
Vstupy:
  • 2 x fiber-optic
  • 2 x error acknowledgement (Ack)
Vstupní signály: Fiber1, Fiber2, Ack1, Ack2
Vstupní napětí: Ack >2.5 V
Výstup: TTL (RS422)
Výstupní signál:
  • K1, K2, K0 + inverted
  • Err + inverted
  • Status S1, status S2, sum status (SSum)
Výstupní frekvence: ≤1 MHz
Výstupní úroveň: TTL: LOW: ≤0.7 V; HIGH: ≥3 V
Počáteční čas: <500 ms
Vlnová délka: ~820 nm
Přenosová vzdálenost: ≤1500 m
Stav výstupu: S1, S2 (configurable)
LED signalizace stavu: 1x power LED (green) 1x overload LED (red) 1x status LED (green) each channel 1x error LED (red) each channel 1x link LED (green) each channel

Mechanické provedení

Rozměry (Š x V x D): 100 x 75 x 53 mm
Ochrana EN 60529: IP 20
Pracovní teplota: -20...+70 °C (without dew)
Připojení:
  • Screw terminal connector
  • 2x ST connector
Typ pouzdra: Mounting on standard rails according to EN 50022

Nákresy

Výkresy

Ke stažení

Datový list

Manuál

Prohlášení o shodě

  • DoC / CoC - LWL-EHR, LWL-SBR, LWL-SHR | stáhnout | zobrazit (EN/DE/BG/CZ/DK/ES/FI/FR/GR/HU/IT/LT/LV/NL/NO/PL/PT/RO/SK/SI, pdf, 2025-04-11 11:32:28)

Podpora

Ondřej Štěpánek
Ondřej Štěpánek
Produktový manažer
BAUMER
Ondřej Štěpánek - QR Kontakt

Zájem či dotaz na produkt

Podobné produkty

FotoProdukt (19) / PopisSkladová dostupnost
ES 93 R
ES 93 R
  • Switch relay box for switching high voltages and currents for the electrical speed switch ES(L) 93
  • Triggering is carried out by the transistor outputs of the ES(L) 93
  • The ES 93 R also conditions an externally supplied AC or DC low voltage
na dotaz
HEAG 150
HEAG 150
  • Signal level shifting from HTL → TTL or TTL → HTL
  • Isolating signal cables to multiple receivers to avoid earth loops
  • Regenerating of signals when transmitting over long distance
  • 1 input unit and 3 output units
na dotaz
HEAG 151
HEAG 151
  • Signal level shifting from TTL → TTL
  • Isolating signal cables to multiple receivers to avoid earth loops
  • Regenerating of signals when transmitting over long distance
na dotaz
HEAG 152
HEAG 152
  • Signal level shifting from HTL → TTL
  • Isolating signal cables to multiple receivers to avoid earth loops
  • Regenerating of signals when transmitting over long distance
na dotaz
HEAG 153
HEAG 153
  • Signal level shifting from TTL → HTL
  • Isolating signal cables to multiple receivers to avoid earth loops
  • Regenerating of signals when transmitting over long distance
na dotaz
HEAG 154
HEAG 154
  • Signal level shifting from HTL → HTL
  • Isolating signal cables to multiple receivers to avoid earth loops
  • Regenerating of signals when transmitting over long distance
na dotaz
HEAG 158
HEAG 158
  • Converting of SinCos signals into TTL and HTL signals
  • Additional interpolation of the signals (multiplying or dividing)
  • Oversampling with 24 MHz
  • Digitally pre-filter
  • Very high output frequency possible
na dotaz
HEAG 159
HEAG 159
  • Converting of SinCos signals into multiplied SinCos signals
  • Multiplying factor 1...128
  • Offset and amplitude adjustment
  • Oversampling with 24 MHz
  • Digitally pre-filter
  • High signal quality
na dotaz
HEAG 160
HEAG 160
  • Converting of SinCos signals into multiplied SinCos signals
  • Additional interpolation of HTL or TTL signals (multiplying or dividing)
  • Oversampling with 24 MHz
  • Digitally pre-filter
  • Very high output frequency possible
na dotaz
HEAG171 R ST 65 LWL-Transmitter
HEAG171 R ST 65 LWL-Transmitter
  • For high interference locations
  • Converting standard square-wave signals into fiber-optic signals
  • Each channel is coupled onto fiber-optic easy-to-fit plug
  • 3 different plug versions available
  • Delay time over a 100 m length of fiber-optic is 1 µs
  • Except of POF all fiber optic cable usable, e. g. PCF 200 μm, silica fiber 50 and 62.5 μm
na dotaz
HEAG172 ST 65 LWL-Transmitter
HEAG172 ST 65 LWL-Transmitter
  • For high interference locations
  • Converting standard square-wave signals into fiber-optic signals
  • Each channel is coupled onto fiber-optic easy-to-fit plug
  • 3 different plug versions available
  • Delay time over a 100 m length of fiber-optic is 1 µs
  • Except of POF all fiber optic cable usable, e. g. PCF 200 μm, silica fiber 50 and 62.5 μm
na dotaz
HEAG173 ST
HEAG173 ST
  • For high interference locations
  • Each channel is coupled onto fiber-optic easy-to-fit plug
  • Reconversion of optical to electrical signals in the receiver control cabinet
  • 3 different plug versions available
  • Delay time over a 100 m length of fiber-optic is 1 µs
  • Except of POF all fiber optic cable usable, e. g. PCF 200 μm, silica fiber 50 and 62.5 μm
na dotaz
HEAG174 ST
HEAG174 ST
  • For high interference locations
  • Each channel is coupled onto fiber-optic easy-to-fit plug
  • Reconversion of optical to electrical signals in the receiver control cabinet
  • 3 different plug versions available
  • Delay time over a 100 m length of fiber-optic is 1 µs
  • Except of POF all fiber optic cable usable, e. g. PCF 200 μm, silica fiber 50 and 62.5 μm
na dotaz
HEAG176 ST 20 LWL-Transmitter
HEAG176 ST 20 LWL-Transmitter
  • For high interference locations
  • Converting standard square-wave signals into fiber-optic signals
  • Each channel is coupled onto fiber-optic easy-to-fit plug
  • 3 different plug versions available
  • Delay time over a 100 m length of fiber-optic is 1 µs
  • Except of POF all fiber optic cable usable, e. g. PCF 200 μm, silica fiber 50 and 62.5 μm
na dotaz
LWL-EHR HTL
LWL-EHR HTL
  • Transmission length up to 1500 m
  • Reconversion of optical signals into electrical signals and generation of status signals
  • Transmission error detection via checksum (CRC)
  • High-precision transmission of signals (Jitter
na dotaz
LWL-EHR TTL
LWL-EHR TTL
  • Transmission length up to 1500 m
  • Reconversion of optical signals into electrical signals and generation of status signals
  • Transmission error detection via checksum (CRC)
  • High-precision transmission of signals (Jitter
na dotaz
LWL-SBR
LWL-SBR
  • Transmission length up to 1500 m
  • Converting standard square-wave signals into optical signals
  • Transmission error detection via checksum (CRC)
  • High-precision transmission of signals (Jitter
na dotaz
LWL-SHR
LWL-SHR
  • Transmission length up to 1500 m
  • Converting standard square-wave signals into optical signals
  • Transmission error detection via checksum (CRC)
  • High-precision transmission of signals (Jitter
na dotaz
Relay modul DS 93 R
Relay modul DS 93 R

Switch relay box for switching high voltages and currents for a digital speed switch (for example DSL or DS 93). Triggering is carried out by the three line drivers.

na dotaz